Abstract
The article considers data of stability of lithium-conducting polymer films based on fluoropolymer F-62 and lithium perchlorate as ionogenic salt versus aqueous solutions of acids and alkalis - hydrochloric acid and lithium hydroxide in pH range 1?13. Both chemical composition change and conductivity shifts of samples are investigated under exposure in water solutions. The research is aimed to estimate the applicability of polymer electrolytes as lithium metal protection from water in lithium-air power sources.
Translated title of the contribution | STABILITY OF LITHIUM-CONDUCTING POLYMER ELECTROLYTES VERSUS AQUEOUS SOLUTIONS OF ACIDS AND ALKALIS |
---|---|
Original language | Russian |
Pages (from-to) | 137-141 |
Number of pages | 5 |
Journal | Международный научно-исследовательский журнал |
Issue number | 10-4 (52) |
DOIs | |
Publication status | Published - 2016 |
GRNTI
- 44.00.00 ENERGETICS
Level of Research Output
- VAK List