ГАЗООХЛАДИТЕЛЬНАЯ УСТАНОВКА ДЛЯ КОМПРЕССОРНЫХЦЕХОВ МАГИСТРАЛЬНЫХ ГАЗОПРОВОДОВ

Леонид Павлович Шелудько, Светлана Анатольевна Гулина, Ирина Юрьевна Горюнова, Глеб Владиславович Власов

Resultado de pesquisa: Articlerevisão de pares

Resumo

Questions of reliability augmentation and efficiency of technological processes of compressor stations of the main gas pipelines using gas-cooling installation of new type are considered. The carried-out assessment of efficiency of use of air coolers of natural gas which showed that during a summer time frame the efficiency of this equipment decreases. Thermodynamic calculation of gas-cooling installation is carried out, and are defined thermodynamic by evaporator parameters, providing the given temperature of technological gas on an input in the trunk. As temperature of the cooling water does not depend on ambient air temperature, and is defined by thermodynamic parameters of the evaporator, it gives the chance of obtaining the given, stable temperature of technological gas for submission it in the trunk. Stabilizing of temperature condition throughout the main gas pipeline will allow to reduce the capacities spent for increase in pressure in TsN. Increase in power of the turbine jet during the summer period after moistening of air on an input in the compressor is calculated.
Título traduzido da contribuiçãoGas-cooler installation for compressor shops of the maigas pipelines
Idioma originalRussian
Páginas (de-até)117-127
Número de páginas11
RevistaВестник Самарского государственного технического университета. Серия: Технические науки
Número de emissão1(57)
Estado da publicaçãoPublished - 2018

Level of Research Output

  • VAK List

Impressão digital

Mergulhe nos tópicos de investigação de “ГАЗООХЛАДИТЕЛЬНАЯ УСТАНОВКА ДЛЯ КОМПРЕССОРНЫХЦЕХОВ МАГИСТРАЛЬНЫХ ГАЗОПРОВОДОВ“. Em conjunto formam uma impressão digital única.

Citar isto