АНАЛИЗ ПРИЧИН ВОЗНИКНОВЕНИЯ ДЕФЕКТОВ ПВХ МЕМБРАНЫ, ВЫЗВАВШИХ ПРОТЕЧКИ МЯГКОЙ КРОВЛИ

科研成果: Article同行评审

摘要

Polymer flexible roll waterproofing materials (membranes) are widely used in the construction of flat and low-slope roofs of buildings and structures. Their projected service life is atleast 20 years, but sometimes it comes much earlier. The results of the analysis of the most probable causes that caused the violation of the continuity of the PVC membrane and theformation of leaks of the soft roof of an industrial building after 1.5 years since its installation are presented. As the most likely factors that caused coating defects (cracks of differenttypes and sizes) and, ultimately, roof leaks, are considered: non-compliance with the requirements for the conditions of transportation, storage and installation of PVC membranes atnegative temperatures, as well as a biological external influencing factor (the corrosive effect of synanthropic bird droppings).
投稿的翻译标题ANALYSIS OF THE CAUSES OF PVC MEMBRANE DEFECTS THAT CAUSED SOFT ROOF LEAKS
源语言Russian
页(从-至)67-72
页数6
期刊Строительные материалы
4
DOI
Published - 2021

Level of Research Output

  • VAK List

指纹

探究 'АНАЛИЗ ПРИЧИН ВОЗНИКНОВЕНИЯ ДЕФЕКТОВ ПВХ МЕМБРАНЫ, ВЫЗВАВШИХ ПРОТЕЧКИ МЯГКОЙ КРОВЛИ' 的科研主题。它们共同构成独一无二的指纹。

引用此